38 kV Class Switchgear Specification Guide

Plan a 38 kV-class switchgear specification by checking system voltage, grounding, insulation, protection, service interfaces and project constraints.

MADE IN USAAmerican components
UL 891Switchboard assemblies
SHORT LEAD TIMESConfirm your project schedule
BUILT FOR YOUR PROJECT

Power distribution, with purpose.

A 38 kV-class specification is a starting point for evaluating equipment in some higher-voltage systems, not proof that a particular switchgear configuration is available or suitable. Before selecting a lineup, establish the system’s nominal voltage and grounding, the equipment’s rated voltage and insulation requirements, and how protection and connected apparatus affect the design. Confirm the exact configuration and ratings with the manufacturer and project engineer before treating it as a product offering.

Separate nominal system voltage from equipment rating

The number 38 kV describes an equipment class in some applications; it should not be substituted for the system’s nominal operating voltage or treated as a complete rating. A project may identify a nominal line-to-line voltage while specifying equipment with a higher maximum rated voltage to accommodate system conditions and required insulation performance. The specification should state both values, name the applicable voltage class, and identify the governing utility or project criteria. Equipment maximum voltage, continuous operating limits, and insulation levels must be confirmed for the specific design.

Ask the electrical engineer or utility to resolve any mismatch between documents that use “38 kV,” another nominal voltage, or a different equipment class. The distinction affects clearances, insulating materials, instrument-transformer selection, terminations, and coordination with connected devices. Do not infer that a 38 kV-class assembly is available simply because the system description uses that value. Configuration, component availability, applicable standards, and ratings are order-specific and require manufacturer confirmation.

Document grounding and line-to-neutral conditions

Line-to-line voltage is the voltage between phases. Line-to-neutral voltage applies where the system has a neutral reference, but a 38 kV-class three-phase application may not expose a usable neutral at the switchgear. State whether the system is solidly grounded, resistance grounded, reactance grounded, ungrounded, or grounded through another arrangement. Include the grounding source, neutral treatment, and expected ground-fault behavior rather than leaving the equipment supplier to infer these conditions from a one-line diagram.

Grounding changes the voltage stress a phase-to-ground insulation system may experience during normal operation and faults. It also affects ground-fault detection, relay settings, instrument-transformer connections, and the duration for which a fault may remain before clearing. If line-to-neutral values are provided, identify whether they are measured values, calculated values, or design assumptions, and explain how the neutral is established. Have the engineer verify phase-to-ground insulation and protection choices for the actual grounding method.

Illustrative close-up of copper busbars in a motor control panel
Illustrative industry photograph · ToT89 / Wikimedia Commons · resized · CC BY-SA 4.0

Set frequency, insulation, and environmental requirements

Specify system frequency explicitly, along with any operating conditions that could affect equipment duty, such as continuous loading, switching frequency, altitude, ambient temperature, moisture, contamination, or exposure to corrosive substances. Do not assume that a voltage-class label alone defines acceptable service conditions. Insulation coordination should address the project’s required power-frequency withstand and impulse withstand levels, as well as the expected switching and lightning environment. The responsible engineer should determine applicable values and confirm that the proposed design meets the project requirements.

The enclosure and insulation approach must suit the actual installation, including indoor or outdoor service, access limitations, cable or bus entry, and maintenance clearances. State whether the design needs particular creepage distance, phase spacing, barriers, or environmental protection, and identify any site conditions that drive those choices. Required standards and tests depend on the equipment type and project specification. Verify them for the proposed assembly; do not assume that UL 891 applies, since that standard concerns low-voltage switchboards rather than 38 kV-class equipment.

Coordinate protection with the complete system

A useful specification gives more than the requested relay functions. Provide available fault-current information, source and transformer data, grounding details, load characteristics, and the intended protection zones. Identify the required circuit-breaker or switching functions, metering, relaying, communications, interlocks, and control-power sources. The engineer should coordinate pickup and time settings with upstream and downstream devices so that a fault is cleared by the intended protective device without compromising selectivity or equipment withstand limits.

Short-circuit rating and interrupting capability are separate checks that depend on the actual system study and selected components. Include the study basis and ask the supplier to confirm that proposed ratings and interfaces align with it. Protection design also depends on whether the equipment connects to transformers, generators, motors, utility sources, or other switchgear, and on how those sources may operate together. Do not treat a nominal voltage class as evidence of adequate fault-duty performance.

Plan interfaces, service coordination, and procurement

Before requesting a quote, provide a current one-line diagram, equipment schedule, site and installation conditions, required lineup arrangement, incoming and outgoing cable or bus details, control schematics, metering and relay requirements, and known utility constraints. Include specified nominal and rated voltages, frequency, grounding method, insulation criteria, available fault current, required short-circuit duty, and any governing standards. Mark open items clearly so engineering review can distinguish confirmed requirements from assumptions.

Check physical and electrical interfaces with transformers, surge arresters, cables, bus transitions, grounding connections, remote controls, and upstream or downstream protection. For projects in Dallas–Fort Worth or elsewhere, delivery planning should account for route, receiving access, unloading responsibility, and site readiness without assuming a local manufacturing facility or installation service. The manufacturer builds and supplies new equipment, can consider custom configurations and American components, and treats shorter lead time as a goal rather than a guarantee. Confirm whether the requested 38 kV-class configuration is actually offered, and validate ratings, component availability, standards, and any U.S.-origin requirements for the specific order.

PROJECT CONSIDERATIONS

Specifications & planning

Review the details that matter for your application. Final specifications and availability should be confirmed for your project.

38 kV Class voltage planning: specifications and planning considerations
Evaluation factorProject information to confirm
Voltage basisNominal system voltage, equipment rated voltage, and applicable maximum voltage
GroundingGrounding method, neutral reference, and expected phase-to-ground fault conditions
Insulation and environmentRequired withstand levels, frequency, installation conditions, and applicable standards
Protection and dutyFault-study basis, interrupting requirements, protection zones, and coordination interfaces